Reasons and solutions for incorrect operation or invalid action of hydraulic cylinder

Aug 27, 2022

(1) The valve core is stuck or the valve hole is blocked. When the valve core of the flow valve or the directional valve is stuck or the valve hole is blocked, the hydraulic cylinder is prone to wrong operation or invalid action. At this time, the contamination status of the oil should be checked; whether the dirt or colloidal precipitation is stuck on the valve core or blocked the valve hole; check the wear status of the valve body.

(2) The piston rod and the cylinder liner are stuck or the hydraulic cylinder is blocked. At this time, no matter how it is controlled, the hydraulic cylinder does not move or moves very little. At this time, it should be checked whether the seal of the piston and piston rod is too tight, whether it has entered dirt and colloidal deposits: whether the axis line of the piston rod and the cylinder liner is aligned, and whether the consumable parts and seals are invalid.

(3) The hydraulic system control pressure is too low. The throttling pressure in the control pipeline may be too high, the flow valve is not well adjusted, the control pressure is not suitable, and the pressure source is affected. At this time, the control pressure source should be checked to ensure that the pressure is adjusted to the standard value of the system.

(4) Enter the gas in the hydraulic system. Mainly due to leaks in the system. At this time, you should check the liquid level of the hydraulic oil tank, the seals and pipe joints on the oil-removing side of the hydraulic pump, and whether the oil-removing strainer is dirty. If so, replenish hydraulic oil, dispose of seals and pipe joints, and clean or replace coarse filter elements.

(5) The hydraulic cylinder starts to move slowly. Under the condition of low temperature, the viscosity of the hydraulic oil is high and the fluidity is poor, resulting in the slow action of the hydraulic cylinder. The improvement method is to replace the hydraulic oil with good viscosity-temperature performance. At low temperature, the heater can be used or the equipment itself can be used to heat up to increase the oil temperature at startup.